The Honeywell RM7895D1011 Burner Control 120V, 60 HZ, AirFlow Switch CHECK, INTERRUPTED Pilot, 10 SEC MAIN Flame ESTABLISHING PERIOD, DELAYED MAIN Valve. On-Off Primary Control with Prepurge, Burner Control for Automatically Fired Gas, Oil or Combination Fuel Single Burner Applications, 120Vac, Interrupted Pilot, Dynamic AirFlow Check, 10 Second Main Flame Establishing Period, 4 Second or 10 Second Pilot Flame Establishing Period, Delayed Main Valve, Selectable Interlocks, Nonvolatile Memory, Functions include Burner Sequencing, Flame Supervision, System Status Indication, System or Self Diagnostics and Troubleshooting
Search Results for: Functional Devices
The Honeywell RM7840G1014 Burner Control 120 V/60 HZ. AirFlow Switch CHECK OPTION.
The Honeywell RM7840M1017 Burner Control 120 V/60 HZ. AirFlow Switch CHECK OPTION. INCLUDES DUST Cover. Microprocessor Based Integrated Burner Control for Automatically Fired Gas, Oil, Coal or Combination Fuel Single Burner Applications, 120Vac, 10 Second or Intermittent Main Flame Establishing Period, 4 Second or 10 Second Pilot Flame Establishing Period, Intermittent Second Stage Pilot Valve, Running Interlocks, Interuppted Pilot, 5 Second Early Spark Termination, 15 Second PostPurge, User Selectable AirFlow Check, Five Function Run/Test Switch, On/Off- LF Proven
The Honeywell RM7840L1026 Burner Control 120V, 50/60 HZ. AirFlow Switch CHECK OPTION. INTERMITTENT Pilot. INCLUDES DUST Cover.
The Honeywell RM7845A1001 Burner Control 120V, 50/60 HZ., Microprocessor Based Integrated Burner Control for Automatically Fired Gas, Oil, Coal or Combination Fuel Single Burner Applications, 120Vac, Interrupted Pilot, Preignition, 15 Second PostPurge, Lockout Interlocks, 10 Second Main Flame Establishing Period, 4 Second or 10 Second Pilot Flame Establishing Period, LHL-LFand HF Proven, -40-140 Degree Ambient Temperature Range
The Honeywell RM7895A1048 Burner Control 120V, 50/60 HZ. TERMINATION OF SPARK UPON DETECTION OF Flame
The Honeywell RM7895B1013 Burner Control 120V, 50/60 HZ. Switch CHECK.
The Honeywell RM7895E1002 Burner Control 120V, 50/60 HZ. On-Off Primary Control with Prepurge, Burner Control for Automatically Fired Gas, Oil or Combination Fuel Single Burner Applications, 120Vac, Intermittent Pilot, Intermittent Main Flame Establishing Period, 15 Second or 30 Second Pilot Flame Establishing Period, Higher Flame Sensor Voltage for Infrared Heater Applications, Selectable Interlocks, Nonvolatile Memory, Functions include Burner Sequencing, Flame Supervision, System Status Indication, System or Self Diagnostics and Troubleshooting, Used with R7847 Only
The Honeywell RM7895C1020 Burner Control 120V, 50/60 HZ. FIXED 10 SEC PFEP,TERMINATION OF SPARK UPON DETECTION OF Flame. On-Off Primary Control with Prepurge, Burner Control for Automatically Fired Gas, Oil or Combination Fuel Single Burner Applications, 120Vac, Interrupted Pilot, 10 Second Main Flame Establishing Period, 10 Second Pilot Flame Establishing Period, Delayed Main Vlave, Selectable Interlocks, Nonvolatile Memory, Functions include Burner Sequencing, Flame Supervision, System Status Indication, System or Self Diagnostics and Troubleshooting, Includes Ignition Cutout During PFEP