The Veris CWLSHTA CO2,Wall,LCD,RH 2%,T-Xmtr,50-95F
SPECIFICATIONS
Application Zone | : | Living Space |
Application | : | Wall |
Brand | : | Veris |
CO2 Measurement Accuracy | : | ±30 ppm ±2% of measured value |
CO2 Measurement Range | : | 0 – 2000 ppm | 0 – 5000 ppm |
CO2 Measurement Repeatability | : | ±20 ppm ±1% of measured value |
CO2 Measurement Resolution | : | 1 ppm |
CO2 Sensor Type | : | NDIR |
Color | : | Cloud White |
Dimension Depth | : | 1.2″ (30 mm) |
Dimension Height | : | 4.8″ (122 mm) |
Dimension Width | : | 3.5″ (89 mm) |
Display Resolution | : | 2 Rows x 8 Characters |
Display Size | : | 1.2″ x 0.6″ (30,5 mm x 14 mm) |
Display Type | : | LCD |
Electrical Wiring Size | : | 24 – 18 AWG (0.22 – 0.75 mm²) |
Enclosure Material | : | ABS Plastic |
Humidity Calibration Certificate | : | None |
Humidity Measurement Accuracy | : | ±2% |
Humidity Measurement Range | : | 0 – 100% RH |
Humidity Measurement Resolution | : | 0.1% RH |
Measurement Type | : | CO2 | Humidity | Temperature |
Mounting | : | Wall |
Operating Humidity | : | 0 – 95% RH, non-condensing |
Operating Temperature | : | 50 – 95 °F (10 – 35 °C) |
Output Specifications | : | 4 – 20 mA | 0 – 5 V | 0 – 10 V |
Outputs | : | Analog output |
Override | : | No |
Product Certification | : | CE |
Product Type | : | Sensor |
Range | : | CWL |
Response Time | : | CO2: <60 seconds for 90% step change |
Setpoint | : | No |
Supply Voltage AC Nominal | : | 24 VAC |
Supply Voltage DC Nominal | : | 20 – 30 VDC |
Temperature Calibration Certificate | : | None |
Temperature Measurement Accuracy | : | ±0.9 °F (±0.5 °C) |
Temperature Measurement Range | : | 50 – 95 °F (10 – 35 °C) |
Temperature Measurement Resolution | : | 0.1 ° |
Temperature Sensor Type | : | Transmitter |
Warranty | : | 5 years |
FEATURES
CWL carbon dioxide (CO2) sensors maximize energy savings, while helping optimize ventilation. These sensors allow ventilation systems to be controlled by the amount of CO2 present in a space. The CWL series detect fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for the space at a given time saving energy and increasing tenant comfort.
- Microprocessor based design increases accuracy and reduces installation time
- Self-calibrating – innovative self-calibration algorithm easy to maintain
- Non-dispersive infrared technology (NDIR) repeatable to +/-20 ppm +/-1% of measured value high accuracy measurement
- Snap-on faceplate no screws required, making installation and service easy
- Field-selectable outputs for operation flexibility
- Integrated probe – integrated transducer and probe eliminates the need to install a separate pick-up tube
- Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) US Patent 5,844,138 HS sensor
- Solid-state, integrated circuit sensor