LWV FCU BN 0-10V HOTEL
Low-Voltage Fan Coil Room Controller: BACnet MS/TP, Analog 0-10 Vdc, Hotel/Lodging
Product Specifications
[Us] rated supply voltage | 10…30 V AC 50/60 Hz |
Application | Low voltage fan coil |
AWG Gauge | AWG 22…AWG 18 |
Brand | Schneider Electric |
By Schneider | Yes |
California proposition 65 | WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov |
Communication Port Protocol | BACnet MS/TP |
Connections – Terminals | Screw terminal |
Depth | 1.18 in (29.97 mm) |
Device Presentation | Without cover |
Device Short Name | SE7300-ECM |
Directives | 89/336/EEC – electromagnetic compatibility |
Economizer | No |
End of commercialization annoucement date | 02/28/2019 |
End of commercialization date | 03/06/2019 |
End of service announcement date | 12/20/2019 |
End of service date | 09/17/2019 |
Final Result for Flywheel performance tracking | Edge control non-recurring |
Height | 4.92 in (124.97 mm) |
Humidity Calibration Certificate | 1 pt |
Humidity Control | No |
Humidity Setting Range | Dehumidification 15…95 % |
Humidification 10…90 % | |
Information Displayed | Temperature – 40…122 °F |
Input Type | Dry contact 1.0 |
Insulation Class | Class II |
internal resistance | >= 2 kOhm |
Life cycle Comment | PEP0482599R- O2- 2018 O2 PWP |
Manufacturer | Schneider Electric |
Market Segment | Lodging/Hotel |
Measurement Accuracy | Temperature +/- 0.9 °F, at 70 °F typically calibrated) |
Net Weight | 0.75 lb(US) (0.34 kg) |
Network Frequency | 50 Hz |
60 Hz | |
Output Current | <= 5 mA universal output |
Output Type | 1 xanalog |
2 xuniversal | |
Output Voltage | 0…10 V DC universal output |
30 V AC universal output | |
PIR Cover | No |
Product Alert | We are currently experiencing delays on this product. As we work to return it to normal, inventory and lead times may not be accurate. Please use the chat feature to contact CCC for additional details |
Product Certifications | CE |
C-tick AS/NZS CISPR 22 | |
FCC CFR 47 part 15 class A | |
UL listed file E27734 CCN XPAX | |
UL listed file E27734 CCN XPAX7 | |
Product Name | SE7000 Series |
Product Or Component Type | Room controller |
Range | EcoStruxure Building Expert |
Range Compatibility | communication card |
relay | |
sensor | |
sensor coverplate | |
temperature sensor | |
Rated Operational Power In Va | 2 VA |
Relative Humidity | 0…95 % RH, non-condensing |
Scheduling | No |
Sensor Type | Temperature: 10 kOhm T2 NTC thermistor |
Standards | CSA C22.2 No 24 |
FCC part 15 subpart B | |
ICES-003 | |
UL 873 | |
Temperature Ambient Operating Range | 32…122 °F (-0…50 °C) |
Temperature Setting Range | 0.9 °F (-17 °C) per step |
40…90 °F (4…32 °C) heating | |
54…100 °F (12…38 °C) cooling | |
Temperature Shipping and Storage Range | -22…122 °F (-30…50 °C) |
Width | 3.42 in (86.87 mm) |
Documents
Application guide | SE7000 Fan Coil Unit Application Guide | |||
Data sheet | SE7300 ECM Series Datasheet | |||
Installation guide | PIR Ready SE7200, SE7300 and SER7300 Series | |||
PIR Ready SE7300f5x45X-ECM Series Installation Guide | ||||
Selection guide | SE7000 Product Comparison Guide |